LVP Technology

Warranty claim — Elex-10 Shot Exploder

Please complete this form to submit your warranty claim. Upload photos or videos of the issue as evidence.

Product information
Problem description
How to test your Elex-10

Working outside the stated conditions may result in the Elex-10 not working as intended, or not working at all.

Which test(s) will you be performing?

Select one, or both if you will perform the full sequence.

Test 1 — Continuity Testing

Conditions

  • Batteries used must be above 8.5 Volts.
  • The test component must form a complete circuit between its two ends (see recommended test components below).
  • The Elex-10 must be dry and clean.

Recommended test components

  • A small conductive wire, or
  • A resistor with resistance less than 390 Ohms.

Step-by-step procedure

  1. Unscrew the battery cap on the bottom of the Elex-10.
  2. Make sure the battery compartment is clear and clean.
  3. Insert both batteries (polarity does not matter).
  4. Screw the battery cap back on — hand tighten only.
  5. Press lightly on one terminal mounted on top of the Elex-10.
  6. Insert the first end of the test component, then release the terminal.
  7. Press lightly on the second terminal.
  8. Insert the second end of the test component, then release the terminal.
  9. Make sure both terminals grip the test component tightly.
  10. Press and hold the Test/Fire button.
  11. While pressing, feel for a "click".
  12. Check both LEDs on the Elex-10.

Result: the continuity test is successful when the LEFT (GREEN) LED lights up.

Please report your results for this test:

Test 2 — Firing Test

Conditions

  • Batteries used must be above 8.5 Volts.
  • The test component must form a complete circuit between its two ends (see recommended test components below).
  • The Elex-10 must be dry and clean.

Recommended test components

  • A small conductive wire, or
  • A resistor with resistance less than 390 Ohms.

Step-by-step procedure

  1. Unscrew the battery cap on the bottom of the Elex-10.
  2. Make sure the battery compartment is clear and clean.
  3. Insert both batteries (polarity does not matter).
  4. Screw the battery cap back on — hand tighten only.
  5. Press lightly on one terminal mounted on top of the Elex-10.
  6. Insert the first end of the test component, then release the terminal.
  7. Press lightly on the second terminal.
  8. Insert the second end of the test component, then release the terminal.
  9. Make sure both terminals grip the test component tightly.
  10. Press and hold the Test/Fire button.
  11. While pressing, feel for a "click".
  12. Check both LEDs — continuity is confirmed when the GREEN LED lights up.
  13. Release the Test/Fire button.
  14. Press and hold the Arm button.
  15. Wait 15 seconds.
  16. The Elex-10 is armed when the RED LED lights up.
  17. Keep the Arm button pressed.
  18. Press the Test/Fire button to fire the device.
  19. Firing was successful when the test component burned through, or the red LED switched off.

Result: firing is successful when the test component burns through, or the red LED switches off.

Please report your results for this test:

Evidence — photos & videos

Take a photo/video with your phone or upload existing files. Accepted: JPG, PNG, WebP, HEIC, MP4, MOV, WebM. Max 10 MB per file.

Audit evidence

Warranty claim records

Date Client Serial no. Purchase date Units Problem Description Diagnostics Files Sent by

Audit evidence

Feedback records

Date Client Project Order Shipment Order date Shipping date Rating Sent by Detail ratings Comment

LVP administration

Account